LQS Epoguard 400 – 2-component solvent-free epoxy coating, coal tar combination

  • Brands:
  • SKU:
  • Status: In stock
  • Capacity: 20kg
  • Quantity : 1000

LQS Epoguard 400 is a 2-component solvent-free and coal tar oil-based epoxy coating system. After application, LQS Epoguard 400 will create a coating with high adhesion and good waterproofing on many types of surfaces, with anti-corrosion ability.

Order now Call to confirm and deliver to your door

Product information

 

APPLICATIONS

LQS Epoguard 400 is a chemical-resistant coating suitable for use in:

  • Wastewater treatment plants
  • Bridge piers submerged in water
  • Steel or concrete storage tanks
  • Oil tanks
  • Steel structure protection
  • Underground structures, concrete roofs, balconies, and terraces

⚠️ Note: LQS Epoguard 400 is not suitable for surfaces in contact with drinking water.


ADVANTAGES

  • Excellent chemical resistance
  • Excellent adhesion to most substrates (concrete, steel, etc.)
  • Good corrosion resistance
  • Durable waterproof coating in chemical and waste-exposed environments
  • Suitable for internal and external applications on structures submerged in water for long periods

TECHNICAL INSTRUCTIONS

Surface Preparation

Concrete:

  • Surface must be sound and have a minimum compressive strength of 25 N/mm²
  • Must be clean, dry, and free of contaminants such as dust, oil, grease, old coatings, and curing agents
  • Weak or dusty concrete must be removed
  • Surface defects like pinholes, voids, cracks, and protrusions must be repaired and leveled

Steel:

  • Same strength and cleanliness requirements as concrete
  • For surfaces exposed to chemicals, abrasive blasting is required to remove rust, old coatings, and scale — at least 95% surface area must be properly treated
  • For surfaces not exposed to chemicals, remove all rust, scale, or foreign materials to achieve a clean, gray-metal finish using approved tools
  • Coating must be applied within 3 hours after surface preparation for all metal substrates

Moisture Check & Primer Application (if needed):

  • Check surface moisture, relative humidity, and dew point before application
  • If moisture < 5% → apply LQS Primer FS
  • If moisture ≥ 5% → apply LQS Primer MB (moisture-tolerant primer)

Mixing Procedure:

  • LQS Epoguard 400 is supplied as a two-component system:
    • Part A: Base Resin
    • Part B: Hardener
  • Mix Part A thoroughly first
  • Then add Part B and mix using a mechanical stirrer, moving the stirrer up and down to ensure complete blending
  • Stir until the mixture is uniform, lump-free, and free of air bubbles or sediment

Coating Application:

  • Apply using brush, roller, conventional sprayer, or airless spray
  • Apply the first coat in one consistent direction
  • Once the first coat has dried (typically within 24 hours), apply the second coat in a perpendicular direction

SAFETY INFORMATION

  • Personal Protection: Wear appropriate protective clothing, gloves, and goggles when using the product
  • Environmental Safety: Do not dispose of into water sources or soil
  • Transport: Not classified as hazardous for transportation
  • Reference: Always consult the Material Safety Data Sheet (MSDS) and related safety documents before use

 

Specifications

TECHNICAL SPECIFICATIONS

Specification LQS Epoguard 400
Component Liquid Epoxy and Coal Tar
Appearance Part A: Black resin

Part B: Light yellow, transparent

Mixture: Black

Density Mixture: ~ 1.0–1.3 kg/liter
Mixing Ratio 3 : 1 (by weight)
Coverage Rate 0.2 – 0.4 kg/m²/layer
Number of Coats Minimum 2 coats
Application Temperature 5 – 35°C
Pot Life ~ 40 minutes (at 25–35°C)
Drying Time Hard dry: 8 – 24 hours

Fully cured: after 7 days

Recoating Interval Minimum: 8 hours

Maximum: 24 hours

Recommended Coats 2–3 coats
Packaging Part A: 15 kg/drum

Part B: 5 kg/drum

Part A + B: 20 kg/set

Shelf Life 12 months (if unopened)
Storage Conditions Store in original, unopened, undamaged packaging

In a cool, shaded place at 10°C – 35°C

 

APPLICATIONS

LQS Epoguard 400 is a chemical-resistant coating suitable for use in:

  • Wastewater treatment plants
  • Bridge piers submerged in water
  • Steel or concrete storage tanks
  • Oil tanks
  • Steel structure protection
  • Underground structures, concrete roofs, balconies, and terraces

⚠️ Note: LQS Epoguard 400 is not suitable for surfaces in contact with drinking water.


ADVANTAGES

  • Excellent chemical resistance
  • Excellent adhesion to most substrates (concrete, steel, etc.)
  • Good corrosion resistance
  • Durable waterproof coating in chemical and waste-exposed environments
  • Suitable for internal and external applications on structures submerged in water for long periods

TECHNICAL INSTRUCTIONS

Surface Preparation

Concrete:

  • Surface must be sound and have a minimum compressive strength of 25 N/mm²
  • Must be clean, dry, and free of contaminants such as dust, oil, grease, old coatings, and curing agents
  • Weak or dusty concrete must be removed
  • Surface defects like pinholes, voids, cracks, and protrusions must be repaired and leveled

Steel:

  • Same strength and cleanliness requirements as concrete
  • For surfaces exposed to chemicals, abrasive blasting is required to remove rust, old coatings, and scale — at least 95% surface area must be properly treated
  • For surfaces not exposed to chemicals, remove all rust, scale, or foreign materials to achieve a clean, gray-metal finish using approved tools
  • Coating must be applied within 3 hours after surface preparation for all metal substrates

Moisture Check & Primer Application (if needed):

  • Check surface moisture, relative humidity, and dew point before application
  • If moisture < 5% → apply LQS Primer FS
  • If moisture ≥ 5% → apply LQS Primer MB (moisture-tolerant primer)

Mixing Procedure:

  • LQS Epoguard 400 is supplied as a two-component system:
    • Part A: Base Resin
    • Part B: Hardener
  • Mix Part A thoroughly first
  • Then add Part B and mix using a mechanical stirrer, moving the stirrer up and down to ensure complete blending
  • Stir until the mixture is uniform, lump-free, and free of air bubbles or sediment

Coating Application:

  • Apply using brush, roller, conventional sprayer, or airless spray
  • Apply the first coat in one consistent direction
  • Once the first coat has dried (typically within 24 hours), apply the second coat in a perpendicular direction

SAFETY INFORMATION

  • Personal Protection: Wear appropriate protective clothing, gloves, and goggles when using the product
  • Environmental Safety: Do not dispose of into water sources or soil
  • Transport: Not classified as hazardous for transportation
  • Reference: Always consult the Material Safety Data Sheet (MSDS) and related safety documents before use

 

Review (0)

Rating LQS Epoguard 400 – 2-component solvent-free epoxy coating, coal tar combination

5 0% | 0 rating
4 0% | 0 rating
3 0% | 0 rating
2 0% | 0 rating
1 0% | 0 rating
Review LQS Epoguard 400 – 2-component solvent-free epoxy coating, coal tar combination
0 characters (minimum 10)